Elevator :

 

Fuji elevator all round application of IT, environment, energy and other fields of technology , and constantly develop suitable for oversea market, safe, efficient, comfortable and convenient products, to create a wealth of urban life to contribute .

 

 

Intelligent security system:                                                                                                                                                                          

 

Fuji elevator intelligent security system, security, equipment monitoring, card, elevator control, information transfer, property management and other areas of value-added services in one integrated platform, to achieve the integration of truly intelligent management. Through the construction of multiple protection system, mobile phone and security system linkage, all-weather service support, Hitachi intelligent security system will provide a comfortable, safe and convenient "the quality of life for users .

     Permanent magnet synchronous technology                                                                                                                                                                                                                    


The use of permanent magnet synchronous technology eliminates the potential problems such as noise aggravation and transmission efficiency decrease due to mechanical wear.

Effectively reduce energy consumption, to meet customer demand in energy saving, practicality, stability and so on.

No.

Name

Description

Operating systems

1

Simplex collective control

This is a fully automatic operation used for a single elevator system. Hall calls in the direction in which the elevator is travelling are responded to sequentially and when all calls in that direction are cleared, calls in the opposite direction are responded to. When there are no more calls, the elevator will stop at the last floor served.

2

Duplex collective control

This is a fully automatic operation used for a two-elevator system. Hall calls are responded to by whichever elevator that can serve the hall call faster. When there are no more calls, one of the elevators will stand by at the stand by floor while the other elevator will stay at the last floor served.

3

Group control

FIBEE

Allows the passenger to preselect the destination floor on the destination floor panel installed at the landing hall. This reduces button operations to one, improving the operability.

4

FI-10

This is a simplified group control system used to operate three or four elevators. The system provides a ring control to allocate the elevator car closed to the floor where a new hall call is registered.

5

FI-100

This is a group control system used to operate three to six elevators in a medium-sized building. This control system uses reference-trajectory control, which is based on the theory used in the highest model of the future reference-trajectory control.

6

FI-600

This is a group control system used to operate three to eight elevators in a large-sized building. This control system consists of three smart systems; future reference-trajectory controllearning system” and intelligent system.

7

Down collective control

For this system, all floors have down” call buttons only, except for the stand by floor, where there is up” call button only. The other operations are the same as in selective-collective and duplex selective-collective operations.

Service functions

1

Automatic return function

After all the calls have been served, the elevator will return to the stand by floor for stand by.

2

Attendant operation

For this system, the stop floor is manually set by an attendant, such as in a department store.

3

Independent operation

This operation system is used when there is a need to serve special passengers. Under this operation, all hall calls are disabled for the elevator and it is reserved for exclusive use of the special passengers.

4

Parking operation

The elevator can be parked at the designated floor with a key switch.

5

Rush-hour schedule operation

All the elevators will automatically return to the stand by floor, after serving the last call during this preset rush-hour timing.

6

Homing operation *3

When a dedicated button is pressed, the other registered destinations are cancelled and the elevator goes directly to the specified floor. This is useful in hospitals, etc., when it is necessary to use the elevator in an emergency.

7

Separated simplex operation

When duplex collective control or group control is used, a selector switch on the control panel is used to switch between parallel operation and independent operation.

8

Interphone system

An interphone system is provided for emergency communication between the elevator and the master unit (in the supervisory panel, etc.).

9

Floor lock-out operation

Specific service floors can be locked-out by activating a switch.

10

Temporary call registration of certain restricted floor

By inputting a pre-programmed code using the car operating board floor buttons, passengers can gain access to certain restricted floors.

11

Door nudging operation

When the door has been open for a certain period of time, a buzzer sounds and the door forcibly closes.

 

No.

Name

Description

Safety functions

1

Abnormal speed protection function

In the event that the elevator is moving downwards at an abnormally high speed, the brakes will be automatically engaged and the elevator will cease operation.

2

Out of door-open zone alarm

In the event that the elevator stops out of the door-open zone of a selected floor, doors will not open, and an alarm will be sounded in the elevator.

3

Rescue operation

When the elevator stops out of the door-open zone, it will move to the nearest floor at slow speed to release passengers.

4

Door safety return system

In the event of door overload, such as when passengers get their fingers, hands or personal belongings caught in the door, this system automatically senses this and either re-closes or re- opens the doors to prevent injury.

5

Micro-leveling

Automatic correction of elevator landing level when subjected to varying car load.

6

Car emergency lighting

In the event of a power failure, an emergency light inside the elevator will be automatically activated.

7

Emergency battery

In the event of a power failure, this emergency supply allows the operation of a light, fan and alarm bell.

8

Multi-beam door sensor

In the event that the beam paths are obstructed, this sensor, installed at the edge of the doors, will keep the doors open.

9

Door signal with multi-beam door sensor

In addition to the multi-beam door sensor, the safety shoe is equipped with a signal that indicates when the doors are starting to close.

10

Door safety edge

Mechanical safety units are installed on both sides (2PCO) or one side (2S2P) of the elevator doors. In the event of passengers coming into contact with the safety edges of closing doors, the doors will immediately reopen.

Accessibility

1

Car floor button flashing

The registered car destination floor button flashes when the car approaches the destination floor

2

Braille plate

Braille plates are mounted next to the operation buttons in the car and hall.

3

Sound button

An electronic tone sounds when the buttons are pressed to confirm call register.

Security functions

1

Intelligent operation security system by card reader (By others)

This function allows controlled access to certain floors by means of a password or ID cards. 
Note: Keypad or ID card-reader system is to be provided and installed by others. Interfacing shall be by means of dry (voltage-free) contacts.

2

CCTV(camera by others, coaxial cable by Hitachi)

This system enables the security personnel to monitor the movement inside the elevator. This will be effective in preventing criminal and mischievous acts inside the elevator. (CCTV system, including wiring, is to be supplied by others.)

Information functions

1

IC auto announcement (English / Thai / Malay)

Preset standard messages are announced to the passengers.

2

Public address speaker

A speaker for background music and public announcements for the building can be installed in the elevator. (Music and announcement systems, including wiring, is to be provided by others)

3

Arrival audio signal

An electrical chime (located at the top and bottom of the elevator) will sound just before the arrival of the elevator.

Energy-saving functions

1

Regenerative system

When traveling downwards with a heavy car load or upwards with a light car load, the traction machine acts as a power generator to transmit power back to the electrical network in the building.

2

Automatic turn-off of elevator light and fan

In the event that the elevator is not in use, the light and ventilation fan in the elevator are automatically turned off to conserve energy.

No.

Name

Description

User services

1

Observation

The walls of the elevator are equipped with windows, giving the elevator interior a more open feel.

2

Door open time adjustment

The duration of the door open timing is tailored to usage conditions, substantially improving operational efficiency.

3

Door open prolong button

In the event that this button on the car operation board is pressed, the elevator doors remain open for a pre-set period of time.

4

Automatic bypass operation

In the event that the elevator is fully loaded, this operation will not respond to any hall calls and will only respond to the car calls.

5

Mischievous call cancellation

In the event that a large number of calls is registered by a small number of passengers, the calls are determined to be mischievous and will be automatically cancelled upon responding to the next call. This eliminates unnecessary stops.

6

Floor "deselect "function

This function allows passengers to cancel the selection of a floor which is accidentally pressed by pressing the button again. (This eliminates unnecessary stops.)

7

Supervisory panel

This panel provides various supervisory operations, including communication and status monitoring.

8

Elevator monitoring system (EMS)

This system shows the real time situation of the elevators such as the elevator position, movement direction and abnormal operation on the PC (Personal Computer) display. It is also possible to turn on/off the elevators and change the service floors of the elevators using the PC.

9

Ion generator

A device that generates ionic microparticles enclosed in water is mounted on top of the car to ensure pleasant air quality inside the elevator.

10

Air conditioner

An evaporative-type cooling unit eliminates the need for pit drainage. This enhances comfort inside the elevator.

Emergency operations

1

Earthquake emergency operation

In the event that an earthquake is detected, the elevator will stop at the nearest floor.

2

Earthquake emergency operation with primary wave sensor

When primary wave of an earthquake are detected, the elevator moves to the nearest floor and stops.

3

Fire emergency operation

In the event of fire, the elevator is automatically brought to the designated floor where it remains inoperative for passengers' safety.

4

Automatic rescue device for power failure

In the event of power failure,this system automatically switches to battery power to bring the elevator to the nearest floor.

5

Emergency operation for power failure

In the event of building power failure,the elevator can be operated by the building standby generator to move the elevator to the designated floor. (Automatic / Automatic and manual)

6

Pit flood operation

Elevator operation is paused when pit flooding is detected.

7

Fireman operation

In the event that the fireman switch is turned on, the elevator returns to the designated floor and will be ready for firemen's use.

Other functions

1

Counterweight safety

A safety device is installed on the counterweight to maintain the rails and prevent falling.

2

Through door

Doors are installed on both sides of the elevator.

3

Freight condition of service lift* 1

The elevator floor is reinforced to enable it to accommodate a larger volume of freight at once.

4

Over voltage detection device

When an abnormal increase in power supply to the elevator system is detected, the power supply will be cut off to prevent damages to the elevator equipment.

5

Maintenance operation

Elevator operates at lower speed during maintenance.

6

Overload detection system

In the event of overloading, this system will activate an audio/ visual signal to prevent the elevator from moving.

7

Nearest landing door operation

In the unlikely event of temporary trouble during operation, the elevator automatically goes to the nearest floor at a low speed and doors will open to prevent passengers from being trapped inside.

8

Hook for protection sheet

The side walls are equipped with hooks to facilitate mounting of protective mats.

9

Checker plate

A steel plate is affixed to the floor of the elevator.

10

Protection plate (stainless steel hairline) (H=300mm)

Protective stainless steel plates are installed to protect the area extending upward 300 mm from the bottom edge of three-side walls in car.

11

Protection plate (stainless steel hairline) (H=1200mm)

Protective stainless steel plates are installed to protect the area extending upward 1,200 mm from the bottom edge of three-side walls in car.

12

Sub-operating panel

Additional floor selection and door open/close buttons are located on the side opposite the main operating panel.

13

Keypad sub car-operating board

In order to comply with the barrier-free code, especially for high-rise buildings, individual car call buttons can be replaced by a keypad system.

14

Inspection Panel

An inspection panel is installed on the top floor.

15

Fire rated door

2 hours fire rated landing door are available where required

16

Emergency landing door

If there is a long distance between floors, doors are installed in a location where the elevator can stop automatically in an emergency.

17

Switch for emergency exit

A switch stops the elevator when the emergency exit door is opened.

18

Switch for door-machine inspection opening

A switch stops the elevator when the door of the door-machine inspection opening is opened.

19

Painted equipment inside hoistway

Equipment in the hoistway is painted black.

20

Electromagnetic compatibility (EMC)

Electromagnetic compatibility function due to EN81-20/50 regulation, etc.

21

Interfacing to building management system

This interfacing shall be done by means of electrical dry contact to the building management system for their monitoring.